X-09 Type 1F (High Security Electronic Lock) Operating Instructions

VIP免费
2024-11-29 0 0 489.21KB 20 页 5.9玖币
侵权投诉
OPERATING
INSTRUCTIONS
X-09TM
Type 1F
HIGH SECURITY ELECTRONIC LOCK
TABLE OF CONTENTS
INTRODUCTION ..............................................................................1
Lock On Back Cover .......................................................................1
DIALING THE X-09........................................................................2
Dialing Methods ...............................................................................2
To Power the Lock ..........................................................................2
Dialing A Combination .....................................................................2
OPEN AND CLOSE THE X-09 (FACTORY COMBINATION) ......................4
To Open the Lock (Using the Factory Combination) ......................4
To Close the Lock ...........................................................................4
X-09 LOCK SETUP .......................................................................5
Set Operating Mode and Change Combinations ............................5
If You Lock the Change Key in the Safe ........................................8
USING THE X-09..........................................................................9
Single Combination Mode ...............................................................9
Dual Combination Mode ................................................................ 9
Supervisory/Subordinate Mode .....................................................10
Correct Method of Closing/Relocking Container...........................11
AUDIT FEATURES OF THE LOCK .....................................................12
To Check the Number of Successful Openings ........................... 12
To Check the Number of Unsuccessful Attempts........................12
GUIDE TO SYMBOLS ...................................................................13
For Technical Support
Call: 1-800-950-4744
1
INTRODUCTION
The X-09 uses sophisticated computer security and makes dialing much easier than that of
traditional combination locks. The microprocessor in the lock recognizes a number as part of a
combination when you change dialing direction. (See the section on Dialing the X-09.)
Note:
The lock is shipped preset to operate in the Single Combination Mode with a
Default Factory Combination of 50-25-50.
LOCK ON BACK COVER
The Lock On Back Cover (LOBC) feature provides a locking mechanism that locks the back
cover in place after installation. The design is such that the back cover cannot be removed
without visible damage unless the combination is known, regardless of whether the lock is locked
or unlocked.
Note:
Because of the LOBC feature, it is not an easy task to remove the back
cover to read the lock serial number after the lock is installed. Since you may
need the serial number of the lock to reset it if the combination is lost or
forgotten, it is important that you keep a record of the lock serial number in a
secure place. If you do not have the serial number, follow the procedure below
to remove the back cover and retrieve the serial number.
To Remove the Lock on Back Cover:
1. Dial the combination(s) to open the lock and
then retract the bolt.
2. Release the container locking bolts.
3. Open the container.
4. Remove the dust cover plate.
5. Locate the lock on back cover pin on the back
cover of the lock case. (See Figure 1.)
6. Turn the dial to the left to extend the bolt. Do
not close the container.
7. Dial the combination(s) to open the lock.
8. Before turning the dial to retract the
bolt, pull out on the unlocking button.
9. While holding the button out, turn the
dial to the right to retract the bolt to
the unlocked position.
10. Remove the back cover screws.
11. Remove the back cover assembly.
12. Look at the label on the large
capacitor on the system card to get
the lock serial number. (See Figure
2.)
Serial
Number
Figure 2 - Serial # on Label on Capacitor
Figure 1 - Lock On Back Cover
Lock On Back
Cover Pin
2
DIALING THE X-09
DIALING METHODS
The user should dial with complete, full wrist turns. Stopping to regrip produces pauses in dialing
activity. This helps the X-09 distinguish between human and robotic dialers.
Note:
The viewing angle of the LCD is restricted from either side as a security
feature of the lock. This feature restricts viewing of combination dialing by the casual
observer. The display may also appear slightly more dim than previous versions of the
X-xx lock.
TO POWER THE LOCK
You should dial to the left (CounterClockWise) to power the lock unless otherwise
instructed for a specific operation. It usually requires 5-10 turns of the dial to
generate sufficient power for lock operations. The lock is considered to be “pow-
ered” as soon as something (number, letter, symbol) appears on the display.
Note:
While the lock is powered, you will notice that the intensity level of the LCD will
vary. The display may appear to become brighter or more dim at different points in
operation. The variations in the display occur due to a security feature of the lock and
should not be of concern to the user.
When you dial to power the lock, it will first display any error conditions that exist on the lock.
If you continue to dial left and if the number of consecutive unsuccessful attempts is three or
more, the unsuccessful attempts count will be displayed along with a lightning bolt. You must slow
down or stop dialing to pause and view the count. The count will disappear when you dial left to
resume operations or when the lock powers down.
DIALING A COMBINATION
The X-09 recognizes a number as being part of a combination when you stop dialing on that
number and then reverse dialing directions. When dialing a combination, you will dial left for the
1st two digits of the combination, dial right for the second two digits, and then dial left
again for the last two digits. When dialing to the left, the numbers will be displayed in an
increasing fashion as you dial. When dialing to the right, the numbers will be displayed in a
decreasing fashion.
Note:
If at any time the dial remains stationary for more than 40 seconds, the lock
will power down (LCD will go blank), requiring the operator to redial the entire combination.
Once the combination has been dialed correctly, you must dial briskly to the right to get an OP
(OPen right) display and to retract the bolt.
Note:
If an incorrect combination is dialed or if the elapsed dialing time of the
combination is less than 10 seconds, a lightning bolt will appear when you dial right to
retract the bolt.
3
If You Pass Your Target Number When Dialing:
Example A: Target Number = 25.
If you pass your target number by 4 or more, continue dialing until you reach the target
number again.
Example B: Target Number = 25.
If you pass the target number by no more than 3 numbers, you may continue dialing until
you reach the target number as in Example A.
An alternative method is to reverse direction slowly and the display will “jump back” 4
numbers. Then you should dial slowly in the original dialing direction for this target number
until you reach the correct number.
Redial Entire Combination If:
A. The screen goes blank before the lock bolt is retracted.
B. A lightning bolt is displayed.
Caution:
An X-09 lock will initiate a timed lockout of 3 minutes when ten
consecutive wrong combinations have been dialed. Each additional unsuccessful
attempt to open the lock will initiate another timed lockout. If the number of
consecutive unsuccessful attempts reaches fifteen, the timed lockout increases
to 4 minutes. The lockout period is only timed while the lock is powered. To
keep the lock powered until the timed lockout has expired, turn the dial every 30
seconds. A successful opening resets the error count.
摘要:

OPERATINGINSTRUCTIONSX-09TMType1FHIGHSECURITYELECTRONICLOCKTABLEOFCONTENTSINTRODUCTION..............................................................................1LockOnBackCover.......................................................................1DIALINGTHEX-09.....................................

展开>> 收起<<
X-09 Type 1F (High Security Electronic Lock) Operating Instructions.pdf

共20页,预览5页

还剩页未读, 继续阅读

声明:本站为文档C2C交易模式,即用户上传的文档直接被用户下载,本站只是中间服务平台,本站所有文档下载所得的收益归上传人(含作者)所有。玖贝云文库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。若文档所含内容侵犯了您的版权或隐私,请立即通知玖贝云文库,我们立即给予删除!
分类:外语学习 价格:5.9玖币 属性:20 页 大小:489.21KB 格式:PDF 时间:2024-11-29

开通VIP享超值会员特权

  • 多端同步记录
  • 高速下载文档
  • 免费文档工具
  • 分享文档赚钱
  • 每日登录抽奖
  • 优质衍生服务
/ 20
客服
关注