Fx3U-232ADP硬件手册

2025-04-09 0 0 1.21MB 3 页 5.8玖币
侵权投诉
This manual confers no industrial property rights or any rights of any other kind,
nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be
held responsible for any problems involving industrial property rights which may
occur as a result of using the contents noted in this manual.
Warranty
Mitsubishi will not be held liable for damage caused by factors found not to be
the cause of Mitsubishi; opportunity loss or lost profits caused by faults in the
Mitsubishi products; damage, secondary damage, accident compensation
caused by special factors unpredictable by Mitsubishi; damages to products
other than Mitsubishi products; and to other duties.
For safe use
This product has been manufactured as a general-purpose part for general
industries, and has not been designed or manufactured to be incorporated in
a device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric
power, aerospace, medicine or passenger movement vehicles, consult with
Mitsubishi Electric.
This product has been manufactured under strict quality control. However
when installing the product where major accidents or losses could occur if the
product fails, install appropriate backup or failsafe functions in the system.
HEAD OFFICE
HIMEJI WORKS
: TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310,
JAPAN
: 840, CHIYODA CHO, HIMEJI, JAPAN
Side
B
Side
A
Side
BJAPANESE ENGLISH
JY997D13701D
Safety Precaution (Read these precautions before use.)
This manual classifies the safety precautions into two categories:
and .
Depending on the circumstances, procedures indicated by may also
cause severe injury.
It is important to follow all precautions for personal safety.
Associated Manuals
How to obtain manuals
For product manuals or documents, consult with the Mitsubishi Electric dealer
from who you purchased your product.
Applicable standards
FX3U-232ADP units made in June, 2005 or later comply with the EC Directive
(EMC Directive) and UL standards (UL, cUL). Further information can be found in
the following manual. However, the FX3UC-32MT-LT does not comply with the EC
Directive (EMC Directive) or UL standards (UL, cUL).
Refer to the FX3U Series Hardware Manual (Manual No. JY997D18801)
Refer to the FX3UC (D, DSS) Series Hardware Manual (Manual No.
JY997D28601)
Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury
or physical damage.
Manual name Manual No. Description
FX3U Series
User’s Manual
- Hardware Edition
JY997D16501
MODEL CODE:
09R516
Explains the FX3U Series PLC
specifications for I/O, wiring,
installation, and maintenance.
FX3UC Series
User’s Manual
- Hardware Edition
JY997D28701
MODEL CODE:
09R519
Explains the FX3UC Series PLC
specifications for I/O, wiring,
installation, and maintenance.
FX3U/FX3UC Series
Programming Manual
- Basic & Applied
Instruction Edition
JY997D16601
MODEL CODE:
09R517
Describes PLC programming for
basic/applied instructions and
devices.
FX Series User’s
Manual
- Data Communication
Edition
JY997D16901
MODEL CODE:
09R715
Explains N:N network, Parallel Link,
Computer Link, Non-Protocol
communication by RS and RS2
instructions/FX2N-232IF.
1. Outline
The FX3U-232ADP communication special adapter (hereinafter called 232ADP) is a
special adapter for RS-232C communication with a 9-pin D-Sub connector.
The 232ADP is an isolated signal exchange unit used for RS-232C serial data
communication between the PLC and an RS-232C device.
1.1 Communication Function
1.2 Incorporated Items
Verify that the following product and items are included in the package:
1.3 External Dimensions, Part Names, and Pin Configuration
1.3.1 External Dimensions and part names
Communication type Function
Computer link Data transfer between the PLC and computer (specified as
the master station) via dedicated protocol.
Non-protocol
communication
Serial communication between the PLC and an RS-232C
device via non-protocol.
Programming
communication
Program transfer or monitoring enabled via the serial port of
the 232ADP.
Remote maintenance Program transfer or monitoring enabled via modem and
phone line connected to the serial port of the 232ADP.
[1] DIN rail mounting groove (DIN rail: DIN46277)
[2] Name plate
[3] Special adapter slide lock:
Used to connect additional special adapters onto the left side of this special
adapter.
[4] Special adapter connector cover:
Remove this cover to connect additional special adapters to the left side.
[5] Direct mounting hole:2 holes of φ4.5 (0.18") (mounting screw: M4 screw)
Not used when connecting to FX3UC Series PLC.
[6] POWER LED (green): Lit while 5V DC power is supplied from main unit.
[7] RD LED (red):
Lit while receiving data from connected RS-232C device.
[8] SD LED (red):
Lit while sending data to connected RS-232C device.
[9] Special adapter connector:
Used to connect this special adapter to PLC main unit or special adapter.
Manual
This
manual
Product
FX
3U
-232ADP
POWER
RD
SD
[3]
[6]
[5]
[7]
[8]
[9]
[10]
[11]
[12]
[14]
[13]
[2]
[4]
[1]
74(2.92")
Weight: Approx. 80g (0.18 lbs)
Special adapter
connector cover
is removed
7(0.28")
90(3.55")
98(3.86")
106(4.18")
17.6
(0.7")
7.5
(0.29")
15.1
(0.6")
1.4 Pin Configuration
The pin configuration of the RS-232C port on the 232ADP is as shown below.
2. Channel Allocation
Up to two communication ports can be added to the main unit.
Communication port channels are automatically allocated. The communication special
adapter closer to the main unit is ch1.
FX
3U
/ FX
3UC
-32MT-LT Series PLC
Using one communication special adapter + communication expansion board
Using two communication special adapters
FX3UC (D, DSS) Series PLC
[10] RS-232C connector (9-pin D-Sub, male):
Connect RS-232C device to this RS-232C connector
[11] Screws to fix the cable connector: Screw holes #4-40UNC (inch screw thread)
[12] DIN rail mounting hook
[13] Special adapter fixing hook
[14] Special adapter connector:
Used to connect communication or analog special adapters to the left side of the
232ADP.
Pin
No. Signal Name Function
1CD
Receive
carrier
detection
Turns ON when carrier for data
transfer is detected.
(RS-232C device to 232ADP)
2RD
(RXD) Receive data Receives data
(RS-232C device to 232ADP)
3SD
(TXD) Send data Sends data
(232ADP to RS-232C device)
4ER
(DTR) Send request
Turns ON when RS-232C
equipment becomes ready for
data transfer.
(232ADP to RS-232C device)
5SG
(GND) Signal ground Signal ground
(232ADP to RS-232C device)
6DR
(DSR) Send enable
Turns ON when send request is
given to RS-232C equipment
(RS-232C device to 232ADP)
7,8,9 Not used Do not wire.
Screws to fix
RS-232C
connector
1
5
6
9
Screw holes:
#4-40UNC
(inch screw
thread)
Analog
special
function
adapter
Analog
special
function
adapter
Analog
special
function
adapter
FX
3U
-
232ADP
Analog
special
function
adapter
Main unit
Communication
expansion board (ch1)
(ch2)
Analog
special
function
adapter
Analog
special
function
adapter
Analog
special
function
adapter
FX
3U
-
232ADP
Analog
special
function
adapter
FX
3U
-
232ADP Main unit
FX
3U
-CNV-BD(ch1)(ch2)
Analog
special
function
adapter
Analog
special
function
adapter
Analog
special
function
adapter
FX
3U
-
232ADP
Analog
special
function
adapter
FX
3U
-
232ADP Main unit
(ch1)(ch2)
3. Installation
For installation/uninstallation details, refer to the following manuals:
Refer to the FX3U Series User's Manual - Hardware Edition.
Refer to the FX3UC Series User's Manual - Hardware Edition.
3.1 Connection to the FX3U Series PLC
Procedure
1) Turn off the power.
Disconnect all the cables connected to the PLC main unit and special adapter,
and demount the main unit and special adapter mounted on DIN rail or
mounted directly using screws.
2) Install an expansion board to the main unit.
For the expansion board installation procedure, refer to the following manual:
Refer to the FX3U Series User's Manual - Hardware Edition
3) Remove the special adapter connector cover
on the expansion board (fig.A).
When connecting this product to another
special adapter, please replace the
'expansion board' in the above description
with a 'special adapter' and perform the
procedure as indicated.
4) Slide the special adapter slide lock
(fig.B) of the main unit.
When connecting this product to another
special adapter, please replace the 'main
unit' in the above description with a 'special
adapter' and perform the procedure as
indicated.
5) Connect the
special adapter
(fig.C) to the
main unit as
shown on the
right.
6) Slide back the
special adapter
slide lock (fig.B)
of the main unit
to fix the special
adapter (fig.C).
Connection precautions
Connect all the high-speed I/O special adapters before connecting other
special adapters when they are used in combination.
Do not connect a high-speed I/O special adapter on the left side of a
communication or analog special adapter.
INSTALLATION
PRECAUTIONS
Make sure to cut off all phases of the power supply externally before
attempting installation or wiring work.
Failure to do so may cause electric shock or damage to the product.
INSTALLATION
PRECAUTIONS
Use the product within the generic environment specifications described in
PLC main unit manual (Hardware Edition).
Never use the product in areas with excessive dust, oily smoke, conductive
dusts, corrosive gas (salt air, Cl2, H2S, SO2, or NO2), flammable gas,
vibration or impacts, or exposed to high temperature, condensation, or rain
and wind.
If the product is used in such conditions, electric shock, fire, malfunctions,
deterioration or damage may occur.
When drilling screw holes or wiring, make sure cutting or wire debris does
not enter the ventilation slits.
Failure to do so may cause fire, equipment failures or malfunctions.
Do not touch the conductive parts of the product directly.
Doing so may cause device failures or malfunctions.
Connect special adapter securely to their designated connectors.
Loose connections may cause malfunctions.
RUN
STOP
FX
3U
-48MR/ES
-48MR/ES
FX
3U
-48M
3)
4)
B
B
A
4)
RUN
STOP
FX
3U
-48MR/ES
-48MR/ES
FX
FX
3U
3U
-48M
-48M
POWER
RD
SD
FX
3U
-232ADP
FX
3U
-48M
6)
C
B
B
5)
5)
5)
6)
3.2 Connection to the FX3UC (D, DSS) Series PLC
Procedure
1) Turn off the power.
Disconnect all the cables connected to the PLC, and demount the PLC from
the DIN rail.
2) Remove the special adapter connector
cover (fig.A).
3) Slide the special adapter slide lock (fig.B)
of the main unit.
when connecting this product to another
special adapter, please replace the 'main
unit' in the above description with a 'special
adapter' and perform the procedure as
indicated.
4) Connect the
special adapter
(fig.C) to the
main unit as
shown on the
right.
5) Slide back the
special adapter
slide lock
(fig.B) of the
main unit to fix
the special
adapter (fig.C).
3.3 Connection to the FX3UC-32MT-LT PLC
Procedure
1) Turn off the power.
Disconnect all the cables connected to the PLC, and demount the PLC from
the DIN rail.
2) Install an expansion board to the main unit.
For the expansion board installation procedure, refer to the following manual:
Refer to the FX3UC Series User's Manual - Hardware Edition
3) Remove the special adapter connector
cover on the expansion board (fig.A).
When connecting this product to another
special adapter, please replace the
'expansion board' in the above
description with a 'special adapter' and
perform the procedure as indicated.
4) Slide the special adapter slide lock (fig.B)
of the main unit.
When connecting this product to another
special adapter, please replace the 'main
unit' in the above description with a 'special
adapter' and perform the procedure as
indicated.
5) Connect the
special adapter
(fig.C) to the
main unit as
shown on the
right.
6) Slide back the
special adapter
slide lock
(fig.B) of the
main unit to fix
the special
adapter (fig.C).
4)
3)
B
A
B
3)
2)
POWER
RD
SD
FX
3U
-232ADP
5)
C
B
B
4)
4)
4)
5)
B
B
A
4)
4)
4)
3)
POWER
RD
SD
FX
3U
-232ADP
6)
C
B
B
5)
5)
5)
6)
4. Wiring
For wiring details, refer to FX Series User's Manual - Data Communication Edition.
5. Specifications
5.1 Applicable PLC
The version number can be checked by monitoring D8001 as the last three digits
indicate it.
5.2 General Specifications
For the general specifications, refer to the manual of the PLC main unit.
The items other than the following are equivalent to those of the PLC main unit.
5.3 Power Supply Specifications
WIRING
PRECAUTIONS
Make sure to cut off all phases of the power supply externally before attempting
installation or wiring work.
Failure to do so may cause electric shock or damage to the product.
WIRING
PRECAUTIONS
Make sure to cut off all phases of the power supply externally before attempting
installation or wiring work.
Failure to do so may cause electric shock or damage to the product.
Make sure to observe the following precautions in order to prevent any damage to
the machinery or accidents due to abnormal data written to the PLC under the
influence of noise:
- Do not bundle the main circuit line together with or lay it close to the main
circuit, high-voltage line or load line.
Otherwise, noise disturbance and/or surge induction are likely to take place. As
a guideline, lay the control line at least 100mm (3.94") or more away from the
main circuit or high-voltage lines.
STARTUP AND
MAINTENANCE
PRECAUTIONS
Do not disassemble or modify the PLC.
Doing so may cause fire, equipment failures, or malfunctions.
* For repair, contact your local Mitsubishi Electric distributor.
Do not drop the product or exert strong impact to it.
Doing so may cause damage.
DISPOSAL
PRECAUTIONS
Please contact a certified electronic waste disposal company for the
environmentally safe recycling and disposal of your device.
TRANSPORT AND
STORAGE PRECAUTIONS
The product is a precision instrument. During transportation, avoid any impacts.
Failure to do so may cause failures in the product. After transportation, verify the
operations of the product.
Model name Applicability
FX3U Series PLC Ver.2.20 or later (from first production)
FX3UC Series PLC Ver.1.00 or later (from first production)
Item Specification
Dielectric withstand
voltage 500 V AC, 1 min Conforming to JEM-1021
Between terminal block
and ground terminal of
PLC main unit
Insulation resistance 5M or more, 500 V DC by
Megger
Item Specification
Current
consumption
30mA
5V DC power is supplied from the internal power supply of
main unit.
5.4 Performance Specifications
Item Specification
Transmission
standard Conforming to RS-232C
Type of isolation Photocoupler isolation
Transmission
distance 15m (49’2") or less
Connection method 9-pin D-Sub connector (male)
Number of occupied
I/O points
0 point (This number is not related to the maximum number
of input/output points of the PLC.)
Communication
method Full-duplex
Baud rate
Computer Link, Non-Protocol Communication:
300/600/1200/2400/4800/9600/19200 bps
Programming Communication:
9600/19200/38400/57600/115200bps
Communication
format
Computer Link (dedicated protocol: format 1/format 4),
Non-Protocol Communication, and Programming
communication
LED display:
LED color Power: green, RD: red, SD: red
FX3U-232ADP
Installation Manual
This manual describes the part names, dimensions, mounting, and
specifications of the product. Before use, read this manual and the manuals of
all relevant products fully to acquire proficiency in handling and operating the
product. Make sure to learn all the product information, safety information, and
precautions.
Store this manual in a safe place so that it can be taken out and read whenever
necessary. Always forward it to the end user.
Registration:
The company and product names described in this manual are registered
trademarks or the trademarks of their respective companies.
Effective September 2007
Specifications are subject to change without notice.
© 2005 Mitsubishi Electric Corporation
Manual Number JY997D13701
Revision D
Date September 2007
摘要:

Thismanualconfersnoindustrialpropertyrightsoranyrightsofanyotherkind,nordoesitconferanypatentlicenses.MitsubishiElectricCorporationcannotbeheldresponsibleforanyproblemsinvolvingindustrialpropertyrightswhichmayoccurasaresultofusingthecontentsnotedinthismanual.WarrantyMitsubishiwillnotbeheldliableford...

收起<<
Fx3U-232ADP硬件手册.pdf

共3页,预览1页

还剩页未读, 继续阅读

声明:本站为文档C2C交易模式,即用户上传的文档直接被用户下载,本站只是中间服务平台,本站所有文档下载所得的收益归上传人(含作者)所有。玖贝云文库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。若文档所含内容侵犯了您的版权或隐私,请立即通知玖贝云文库,我们立即给予删除!
分类:行业资料 价格:5.8玖币 属性:3 页 大小:1.21MB 格式:PDF 时间:2025-04-09

开通VIP享超值会员特权

  • 多端同步记录
  • 高速下载文档
  • 免费文档工具
  • 分享文档赚钱
  • 每日登录抽奖
  • 优质衍生服务
/ 3
客服
关注